Options
Kouro Renaer, Samir Felipe
A Survey on Capacitor Voltage Control in Neutral-Point-Clamped Multilevel Converters
2022-02-01, Alepuz, Salvador, Busquets-Monge, Sergio, Nicolás-Apruzzese, Joan, Filbà-Martínez, Àlber, Bordonau, Josep, Yuan, Xibo, Kouro Renaer, Samir Felipe
Neutral-point-clamped multilevel converters are currently a suitable solution for a wide range of applications. It is well known that the capacitor voltage balance is a major issue for this topology. In this paper, a brief summary of the basic topologies, modulations, and features of neutral-point-clamped multilevel converters is presented, prior to a detailed description and analysis of the capacitor voltage balance behavior. Then, the most relevant methods to manage the capacitor voltage balance are presented and discussed, including operation in the overmodulation region, at low frequency-modulation indexes, with different numbers of AC phases, and with different numbers of levels. Both open- and closed-loop methods are discussed. Some methods based on adding external circuitry are also presented and analyzed. Although the focus of the paper is mainly DC–AC conversion, the techniques for capacitor voltage balance in DC–DC conversion are discussed as well. Finally, the paper concludes with some application examples benefiting from the presented techniques.
Step-up partial power DC-DC converters for two-stage PV systems with interleaved current performance
2018-02-01, Zapata, Jaime Wladimir, KOURO RENAER, SAMIR FELIPE, Carrasco, Gonzalo, Hugues Renaudineau
This work presents a partial power converter allowing us to obtain, with a single DC-DC converter, the same feature as the classical interleaved operation of two converters. More precisely, the proposed topology performs similarly as the input-parallel output-series (IPOS) configuration reducing the current ripple at the input of the system and dividing the individual converters power rating, compared to a single converter. The proposed topology consists of a partial DC-DC converter processing only a fraction of the total power, thus allowing high efficiency. Experimental results are provided to validate the proposed converter topology with a Flyback-based 100 W test bench with a transformer turns ratio n 1 = n 2 . Experimental results show high performances reducing the input current ripple around 30 % , further increasing the conversion efficiency.
Harmonic Impedance Model of Multiple Utility-Interactive Multilevel Photovoltaic Inverters
2022-12-01, Rojas, Christian A., Kouro, Samir, Inzunza, Ruben, Mitsugi, Yasuaki, Alcaide, Abraham M.
An important requirement of the power grid with high penetration of renewable energy sources is the mitigation of potential harmonic interactions between different distributed large grid-tie inverters and the mains. This work presents the harmonic interaction between multiple multilevel photovoltaic (PV) inverters based on the well-known T-type neutral-point-clamped inverter (3L-TNPC). The multiple 3L-TNPC is connected in parallel to a common ac bus by using distribution voltage feeders. The analysis is performed by using the Norton equivalence model of each power circuit, its admittance matrix modeling, and the potential overall impedance resonances with the ac grid. The main contribution of this work is the development of a current harmonic injection model of the system operating under a polluted voltage grid for harmonic analysis, while overall filtering design restrictions due to impedance limits based on current and voltage standards are considered. The proposed impedance Norton model is compared with the electromagnetic transient model (EMT model) by using comprehensive simulations, showing good match between both models.
Step-down partial power DC-DC converters for two-stage photovoltaic string inverters
2019-01-01, Zapata, Jaime Wladimir, KOURO RENAER, SAMIR FELIPE, Carrasco, Gonzalo, Meynard, Thierry A.
Photovoltaic (PV) systems composed by two energy conversion stages are attractive from an operation point of view. This is because the maximum power point tracking (MPPT) range is extended, due to the voltage decoupling between the PV system and the dc-link. Nevertheless, the additional dc-dc conversion stage increases the volume, cost and power converter losses. Therefore, central inverters based on a single-stage converter, have been a mainstream solution to interface large-scale PV arrays composed of several strings connected in parallel made by the series connections of PV modules. The concept of partial power converters (PPC), previously reported as a voltage step-up stage, has not addressed in depth for all types of PV applications. In this work, a PPC performing voltage step-down operation is proposed and analyzed. This concept is interesting from the industry point of view, since with the new isolation standards of PV modules are reaching 1500 V, increasing both the size of the string and dc-link voltage for single-stage inverters. Since grid connection remains typically at 690 V, larger strings impose more demanding operation for single-stage central inverters (required to operate at lower modulation indexes and demand higher blocking voltage devices), making the proposed step-down PPC an attractive solution. Theoretical analysis and an experimental test-bench was built in order to validate the PPC concept, the control performance and the improvement of the conversion efficiency. The experimental results corroborate the benefits of using a PPC, in terms of increasing the system efficiency by reducing the processed power of the converter, while not affecting the system performance.
Editorial: Special issue on modular multilevel converters, 2015
2015-01-01, Perez, Marcelo A., Bernet, Steffen, Rodriguez, Jose, KOURO RENAER, SAMIR FELIPE
The articles in this special issue focus on the latest achievements of modular multilevel converters regarding the development of new circuit configurations, converter models, modulation strategies, and control schemes.
Dual-Boost Inverter for PV Microinverter Application—An Assessment of Control Strategies
2022-06-11, Lopez-Caiza, Diana, Renaudineau, Hugues, Muller, Nicolas, Flores-Bahamonde, Freddy, KOURO RENAER, SAMIR FELIPE, Rodriguez, Jose
Photovoltaic (PV) microinverters have grown rapidly in the small-scale PV market, where typical two-stage converters are used to connect one PV module to the single-phase AC grid. This configuration achieves better performance in terms of energy yield compared with other PV configurations. However, the conversion efficiency of a two-stage system is the main drawback, especially when a high-voltage gain effort is required. In this context, single-stage microinverter topologies have been recently proposed since only one power conversion stage is required to extract the maximum power of the PV module and inject the AC power to the grid. This single-stage configuration allows considerable improvement of the overall efficiency of microinverters by reducing the number of elements in the system. However, the main challenge of these topologies is their control, since all variables of the converter are composed by the AC waveform with DC-bias. In this paper, four control strategies are analyzed for the mainstream single-stage topology, which is the dual-boost inverter (DBI). Classical linear control and three non-linear strategies, namely finite control set–model predictive control, flatness-based control, and sliding mode control, are detailed. The main contribution of this work is a complete comparison of the control strategies, to give insights into the most suitable control strategy for the DBI in PV microinverter application.
Power production losses study by frequency regulation in weak-grid-connected utility-scale photovoltaic plants
2016-01-01, Muñoz-Cruzado-Alba, Jesús, Rojas, Christian A., KOURO RENAER, SAMIR FELIPE, Díez, Eduardo Galván
Nowadays, an increasing penetration of utility-scale photovoltaic plants (USPVPs) leads to a change in dynamic and operational characteristics of the power distribution system. USPVPs must help to maintain the system stability and reliability while implementing minimum technical requirements (MTRs) imposed by the utility grid. One of the most significant requirements is about frequency regulation (FR). Overall production of USPVPs is reduced significantly by applying FR curves, especially in weak grids with high rate of frequency faults. The introduction of a battery energy storage system (BESS) reduces losses and improves the grid system reliability. Experimental frequency and irradiance data of several weak grids have been used to analyse USPVPs losses related to FR requirements and benefits from the introduction of a BESS. Moreover, its economic viability is showen without the need for any economic incentives.
Transformerless partial power converter topology for electric vehicle fast charge
2023-01-01, Pesantez, Daniel, Renaudineau, Hugues, Rivera, Sebastian, Peralta, Alejandro, Marquez Alcaide, Abraham, Kouro, Samir
Increasing the power rating of electric vehicles (EV) fast charging stations to reduce charging times is considered critical to accelerate the adoption of electric vehicles. Besides increasing the power, other drivers pushing the development of EV fast chargers include the improvement of efficiency and reliability. Partial power converters (PPC) have emerged as an interesting option for some of the power converter stages in fast charging stations due to their potential to increase efficiency and power rating. However, some PPCs operate as switched autotransformers by using high frequency (HF) isolation transformers but without providing galvanic isolation. This is a drawback due to cost, size and losses introduced by the transformer. This paper presents a transformerless DC–DC Type I step-up PPC for a DC–DC regulation converter for EV fast charging stations. The proposed converter replaces the transformer commonly used in Type I PPC by an impedance network, resulting in a more efficient, cheaper, and less complex converter option. This concept is verified through simulations and experimentally validated with a laboratory prototype.
Charging Infrastructure and Grid Integration for Electromobility
2023-04-01, Rivera, Sebastian, Goetz, Stefan M., Kouro, Samir, Lehn, Peter W., Pathmanathan, Mehanathan, Bauer, Pavol, Mastromauro, Rosa Anna
Electric vehicle (EV) charging infrastructure will play a critical role in decarbonization during the next decades, energizing a large share of the transportation sector. This will further increase the enabling role of power electronics converters as an energy transition technology in the widespread adoption of clean energy sources and their efficient use. However, this deep transformation comes with challenges, some of which are already unfolding, such as the slow deployment of charging infrastructure and competing charging standards, and others that will have a long-term impact if not addressed timely, such as the reliability of power converters and power system stability due to loss of system inertia, just to name a few. Nevertheless, the inherent transition toward power systems with higher penetration of power electronics and batteries, together with a layer of communications and information technologies, will also bring opportunities for more flexible and intelligent grid integration and services, which could increase the share of renewable energy in the power grid. This work provides an overview of the existing charging infrastructure ecosystem, covering the different charging technologies for different EV classes, their structure, and configurations, including how they can impact the grid in the future
Harmonic Impedance Model of Multiple Utility-Interactive Multilevel Photovoltaic Inverters
2022-12-01, Rojas, Christian A., Kouro, Samir, Inzunza, Ruben, Mitsugi, Yasuaki, Alcaide, Abraham M.
An important requirement of the power grid with high penetration of renewable energy sources is the mitigation of potential harmonic interactions between different distributed large grid-tie inverters and the mains. This work presents the harmonic interaction between multiple multilevel photovoltaic (PV) inverters based on the well-known T-type neutral-point-clamped inverter (3L-TNPC). The multiple 3L-TNPC is connected in parallel to a common ac bus by using distribution voltage feeders. The analysis is performed by using the Norton equivalence model of each power circuit, its admittance matrix modeling, and the potential overall impedance resonances with the ac grid. The main contribution of this work is the development of a current harmonic injection model of the system operating under a polluted voltage grid for harmonic analysis, while overall filtering design restrictions due to impedance limits based on current and voltage standards are considered. The proposed impedance Norton model is compared with the electromagnetic transient model (EMT model) by using comprehensive simulations, showing good match between both models.