Thesis:
Diferentes enfoques para mejorar la transferencia de calor en una cavidad diferencialmente calentada

datacite.subject.fosEngineering and technology::Mechanical engineering
dc.contributor.correferenteGers, Romain
dc.contributor.departmentDepartamento de Mecánica
dc.contributor.guiaSkurtys, Olivier Fernand
dc.coverage.spatialCampus Casa Central Valparaíso
dc.creatorHuerta Rojo, Pablo Iván
dc.date.accessioned2025-09-09T14:21:34Z
dc.date.available2025-09-09T14:21:34Z
dc.date.issued2022-12
dc.description.abstractEsta investigación es sobre el estudio del efecto producido al interior de una cavidad diferencialmente calentada (CDC) cuando se incorpora un obstáculo (actuador pasivo) o excitadores térmicos locales (actuadores activos). Los excitadores aplicados en las paredes isotérmicas se posicionan de forma no-simétrica para complementar los resultados reportados por Thiers et al. [1]. El ratio de aspecto de la CDC (altura sobre ancho) es 4, el fluido de trabajo es aire y el número de Rayleigh basado en la altura de la cavidad es 9×107, por lo que el flujo convectivo es laminar. El objetivo principal de este trabajo es mejorar la transferencia de calor global utilizando ambos enfoques mencionados. Se realizan simulaciones numéricas usando el solver Nek5000 que utiliza el método de los elementos espectrales de alto orden. Por una parte, el actuador pasivo aumentó la transferencia de calor global en un 4,39% y un incremento local del 80% fue obtenido. Por otra parte, después de considerar diferentes posiciones, frecuencias y fases entre un par de excitadores se llegó a la conclusión que la distribución no-simétrica no mejora la transferencia de calor global en comparación al mejor caso reportado por Thiers et al. [1]. La mejor posición para aumentar la transferencia de calor se ubica a la altura del 70% de la pared caliente y a la altura del 30% de la pared fría. En esta posición se obtiene un incremento del 5,5%es
dc.description.abstractThis research deals with the study of the effect produced inside a differentially heated cavity (DHC) when an obstacle (passive actuator) or a pair of thermal disturbances (active actuators) is incorporated. The thermal disturbances applied to isothermal walls are positioned non-symmetrically to complement the results reported by Thiers et al. [1]. The aspect ratio of the DHC (height over width) is 4, the working fluid is air, and the Rayleigh number based on the height of the cavity is 9×107, so the convective flow is laminar. The main objective of this work is to improve the overall heat transfer using the both mentioned approaches. Numerical simulations are performed using the high-order spectral element method fluid dynamics solver Nek5000. On the one hand, the passive actuator enhanced the global heat transfer by 4,39% and a local increase up to 80% was obtained. On the other hand, after considering different positions, frequencies and phases between a pair of thermal disturbances, it was concluded that the non-symmetrical configuration does not enhance the global heat transfer in comparison with the best case reported by Thiers et al. [1]. The best position to enhance the heat transfer is 70% of the hot plate height and 30% of the cold plate height. At this position this increase reaches 5,5%en_US
dc.description.degreeMagíster en Ciencias de la Ingeniería Mecánica
dc.driverinfo:eu-repo/semantics/masterThesis
dc.format.extent112 páginas
dc.identifier.barcode3560902039220
dc.identifier.doi10.71959/9fm6-1g40
dc.identifier.urihttps://cris.usm.cl/handle/123456789/4119
dc.identifier.urihttps://doi.org/10.71959/9fm6-1g40
dc.language.isoes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsA. Internet abierta repositorio.usm.cl y otros repositorios a que la USM se adscriba.
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectConveccion natural
dc.subjectDinámica de Fluidos Computacional (CFD)
dc.subjectCavidad diferencialmente calentada
dc.subjectModificación de la transferencia de calor
dc.subjectNek5000
dc.subject.ods4 Educación de calidad
dc.titleDiferentes enfoques para mejorar la transferencia de calor en una cavidad diferencialmente calentada
dspace.entity.typeTesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MC_PH_2022.pdf
Size:
20.14 MB
Format:
Adobe Portable Document Format