Thesis:
Análisis crítico y propuesta tecnológica de actualización del sistema de enfriamiento de tope Torres E-955 y E-1301 ENAP Refinería Aconcagua

dc.contributor.correferenteRamirez Livingston, Daniel Alberto
dc.contributor.departmentDepartamento de Ingeniería Química y Ambiental
dc.contributor.guiaLazo Acuña, Andrea Paola
dc.contributor.otherRamírez Livingston, Daniel Alberto
dc.coverage.spatialCampus Casa Central Valparaíso
dc.creatorToro Brito, Diego Alejandro
dc.date.accessioned2026-10-01T15:32:47Z
dc.date.available2026-10-01T15:32:47Z
dc.date.issued2017
dc.descriptionCatalogado desde la version PDF de la tesis.es_CL
dc.description.abstractEn este trabajo de tesis se analizó y simuló la capacidad de enfriamiento del tope de la separadora C3/C4 E-955 de la unidad de LPG3 y la separadora propano/propileno E-1301 de la unidad DIPE de ENAP Refinerías Aconcagua, con el objetivo de identificar posibles problemas operacionales y sus alternativas de mitigación. Considerando las condiciones actuales de operación, se determinó que los requerimientos energéticos de tope de las unidades E-955 y E-1301 son 2848 [kW] y 7615 [kW] respectivamente. El desempeño actual de los aeroenfriadores obtenidos mediante la simulación de los procesos, indica que la capacidad real de enfriamiento de la bahía de aeroenfriadores de la unidad E-955 es de 3032 [kW], menor a la que se tiene por diseño de 3954 [kW], lo que explica los problemas observados cuando la temperatura ambiente bordea los 27°C ambientales. Si bien en un principio esta disminución se atribuía a ensuciamiento y desgastes propios del equipo, mediante la revisión de condiciones en terreno y la simulación del proceso, fue posible determinar que el problema principal se debe a una mala distribución de carga. El desempeño actual de la bahía de aeroenfriadores de la separadora E-1301 obtenidos mediante simulación es de 7788[kW] condición menor a la de diseño de 9000 [kW], lo que también explicaría su baja en rendimiento a temperaturas ambientales cercana a los 27°C. Si bien, ambas unidades son capaces de satisfacer los requerimientos energéticos propios de cada unidad, a temperaturas superiores a 27°C, no logran condensar todo el producto de tope, siendo 29°C ambientales limite energético de la separadora E-955 y 32°C para la separadora E-1301. Un análisis histórico a las temperaturas ambientales de la zona de Concon, muestra que (...).es_CL
dc.description.abstractIn this Thesis Work overhead cooling capacity of the fractioning column C3/C4 E-955 in LPG3 Unit was analyzed and simulated as well as the cooling capacity of the fractioning column of propane propylene E-1301 in the DIPE Unit at ENAP Refinerias Aconcagua, with the objective of identifying possible operational problems and its mitigation alternatives. Considering the actual operation conditions, it was determined that the overhead energetic requirements of devices E-955 and E-1301 were 2848[kW] and 7615[kW] respectively. The actual performance of the air coolers obtained from the process simulation, indicates that the real cooling capacity of the air coolers bay of unit E-955 is 3032[kW], less than the design value of 3954[kW], this explains the problems observed when room temperature is near 27°C. Even though in the beginning this decrease in cooling capacity was attributed to fouling and deterioration on the devices, on site revisions and simulation of the process were helpful in assessing and recognizing that the problem was due to an uneven fee d distribution. The actual performance of the bay of air coolers of the splitter E-1301 obtained through simulation is of 7788[kW] less than the design value of 9000[kW], this also explains the reduced efficiency (output) at room temperatures near 27 Celsius degrees. Even though both units are capable of satisfying the energy requirements of their respective units, temperatures that exceed 27°C aren’t capable of condensing all of the overhead products, an energetic limit of temperature was established for both columns, 29°C in the Column E-955 and 32°C in the fractioning column E-1301. An historical analysis of ambient temperatures in the city of Concon, shows that (...).eng
dc.description.degreeMagíster en Ciencias de la Ingeniería Química
dc.format.extent149 páginas
dc.format.mediumCD ROM
dc.identifier.barcodeMC_DT_2017
dc.identifier.doi10.71959/nen2-0s28
dc.identifier.urihttps://cris.usm.cl/handle/123456789/4713
dc.identifier.urihttps://doi.org/10.71959/nen2-0s28
dc.language.isoes
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsB - Solamente disponible para consulta en sala (opción por defecto)
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subjectAeroenfriadores
dc.subjectCapacidad de enfriamiento
dc.subjectSimulación de procesos
dc.subjectDestilación
dc.subjectAspen Hysys
dc.titleAnálisis crítico y propuesta tecnológica de actualización del sistema de enfriamiento de tope Torres E-955 y E-1301 ENAP Refinería Aconcagua
dc.typeTesis de Pregrado
dc.type.driverinfo:eu-repo/semantics/masterThesis
dspace.entity.typeTesis
usm.date.thesisregistration2017
usm.identifier.thesis4500014416