Thesis:
Evaluación integral de un data center en Chile: considerando aspectos técnicos, ambientales y económicos

datacite.subject.fosEngineering and technology
dc.contributor.correferenteOlmedo Hidalgo, Juan Carlos
dc.contributor.correferenteFuentealba Bugueño, Luis Alberto Javier
dc.contributor.departmentDepartamento de Mecánica
dc.contributor.guiaCuneo Hervieux, Elio
dc.coverage.spatialCampus Santiago Vitacura
dc.creatorBaltazar Olivares, Gabriel Antonio
dc.date.accessioned2026-11-23T12:38:47Z
dc.date.available2026-11-23T12:38:47Z
dc.date.issued2026-09
dc.description.abstractEsta tesina evalúa comparativamente la localización de un data center con un consumo de 30 MW en Chile, considerando emplazamientos representativos de las macrozonas Norte, Centro y Sur. El problema surge de que la expansión de esta infraestructura digital exige decisiones que combinan disponibilidad eléctrica, eficiencia energética, uso de agua, conectividad, permisos, inversión y continuidad operacional, mientras la discusión nacional se ha concentrado principalmente en proyectos individuales y en la zona central. Para aislar el efecto territorial se definió una arquitectura común de 25 MW de carga TI, estándar Tier III y refrigeración híbrida directa al chip, aplicada a Antofagasta, Valparaíso y Concepción. Sobre esta base se modelaron el PUE, el WUE directo e indirecto, el CAPEX, los costos de energía y transmisión y el costo total de propiedad a veinte años. Además, se cuantificaron recursos de flexibilidad mediante UPS, cargas informáticas diferibles y almacenamiento térmico, y se desarrollaron sensibilidades, puntos de quiebre y escenarios integrados. Los resultados muestran que Concepción alcanza el menor TCO, con 383,86 MUSD, seguida por Valparaíso con 386,15 MUSD y Antofagasta con 427,61 MUSD. La diferencia de 0,6 % entre Centro y Sur es inferior a la incertidumbre propia de una prefactibilidad, por lo que ambas alternativas conforman la lista corta general. Concepción presenta el menor PUE y mejora a alta utilización; Valparaíso registra el menor CAPEX y resulta más robusta ante una ocupación gradual; Antofagasta no lidera el caso de propósito general, pero adquiere valor estratégico para edge minero, analítica industrial y procesos batch cuando existe demanda ancla, infraestructura habilitante y un contrato energético favorable. El WUE indirecto es menor en el Norte, aunque este resultado no sustituye la evaluación física y jurídica del agua en cada predio. La flexibilidad es (...).es
dc.description.abstractThis thesis comparatively assesses the siting of a 30 MW colocation data center in Chile using representative locations in the Northern, Central, and Southern macrozones. The research addresses a decision problem in which power availability, energy efficiency, water use, digital connectivity, permitting, investment, and operational continuity must be evaluated jointly, whereas the national debate has largely focused on individual projects and the central area. To isolate the territorial effect, a common technical architecture was defined: 25 MW of IT load, Tier III availability, and hybrid direct-to-chip cooling. This architecture was evaluated in Antofagasta, Valparaíso, and Concepción. The study modeled PUE, direct and indirect WUE, CAPEX, energy and transmission costs, and a twenty-year total cost of ownership. It also quantified flexibility resources based on UPS capacity, deferrable computing workloads, and thermal energy storage, and developed sensitivity tests, break-even values, and integrated scenarios. The results show that Concepción has the lowest TCO at USD 383.86 million, followed by Valparaíso at USD 386.15 million and Antofagasta at USD 427.61 million. The 0.6% difference between the Central and Southern cases is below the uncertainty expected at pre-feasibility level; therefore, both locations form the general shortlist. Concepción achieves the lowest PUE and improves at high utilization, while Valparaíso has the lowest CAPEX and is more robust under gradual occupancy. Antofagasta does not lead the general-purpose case, but it can provide strategic value for mining edge computing, industrial analytics, and batch processing when an anchor demand, enabling infrastructure, and a favorable electricity contract are available. The Northern case also has the lowest indirect WUE under the adopted assumptions, although this indicator does not replace a site-specific assessment of physical and legal water availability. Flexibility is (...).en_US
dc.description.degreeMagíster en Economía Energética
dc.driverinfo:eu-repo/semantics/masterThesis
dc.format.extent131 páginas
dc.identifier.barcodeMP_GB_2026
dc.identifier.doi10.71959/h893-t373
dc.identifier.urihttps://cris.usm.cl/handle/123456789/7334
dc.identifier.urihttps://doi.org/10.71959/h893-t373
dc.language.isoes
dc.publisherUniversidad Técnica Federico Santa María
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/
dc.subjectCentro de datos
dc.subjectLocalización de infraestructura
dc.subjectEficiencia energética
dc.subjectConsumo de agua
dc.subjectAlmacenamiento
dc.subjectConectividad digital
dc.subject.ods9 Industria, innovación e infraestructura
dc.subject.ods7 Energía asequible y no contaminante
dc.subject.ods11 Ciudades y comunidades sostenibles
dc.titleEvaluación integral de un data center en Chile: considerando aspectos técnicos, ambientales y económicos
dc.type.driverinfo:eu-repo/semantics/masterThesis
dspace.entity.typeTesis

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MP_GB_2026.pdf
Size:
3.27 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: